in Analytical Chemistry by (790 points)
How can the concentration of a particular substance in a given sample be determined using colorimetry, and what are the factors that affect the accuracy of the measurement?

1 Answer

0 votes
by (530 points)
Colorimetry is a technique used to determine the concentration of a particular substance in a given sample by measuring the absorbance of light at a specific wavelength. The principle behind colorimetry is the Beer-Lambert Law, which states that the absorbance of a solution is directly proportional to its concentration and the path length of the light through the sample. The equation for the Beer-Lambert Law is:A =   c  lwhere A is the absorbance,  is the molar absorptivity  a constant for a specific substance at a specific wavelength , c is the concentration of the substance, and l is the path length of the light through the sample  usually the width of the cuvette .To determine the concentration of a substance using colorimetry, follow these steps:1. Prepare a series of standard solutions with known concentrations of the substance of interest. These solutions will be used to create a calibration curve.2. Measure the absorbance of each standard solution at the specific wavelength using a colorimeter or spectrophotometer. Record the absorbance values.3. Plot the absorbance values against the known concentrations of the standard solutions to create a calibration curve. The curve should be linear, and the equation of the line can be determined  y = mx + b, where y is absorbance, x is concentration, m is the slope, and b is the y-intercept .4. Measure the absorbance of the unknown sample at the same wavelength used for the standard solutions.5. Use the equation of the calibration curve to calculate the concentration of the substance in the unknown sample by substituting the measured absorbance value into the equation and solving for the concentration  x .Factors that affect the accuracy of colorimetric measurements include:1. Instrumental factors: The accuracy and precision of the colorimeter or spectrophotometer, as well as the cleanliness and quality of the cuvettes, can affect the accuracy of the measurements.2. Sample preparation: Inaccuracies in the preparation of the standard solutions or the dilution of the unknown sample can lead to errors in the concentration determination.3. Interference from other substances: The presence of other substances in the sample that also absorb light at the same wavelength can lead to inaccuracies in the measurement. In such cases, selecting a different wavelength or using a more selective analytical method may be necessary.4. Deviations from the Beer-Lambert Law: Some substances may not follow the Beer-Lambert Law at high concentrations due to factors such as aggregation or chemical interactions. In these cases, working with lower concentrations or using alternative methods may be necessary.5. Temperature and pH effects: Changes in temperature or pH can affect the absorbance of some substances. It is essential to maintain consistent temperature and pH conditions throughout the experiment to ensure accurate results.
Welcome to Sarvan Science Q&A, where you can ask questions and receive answers from other members of the community.
...